Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Nefrologia (Engl Ed) ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38609756

RESUMEN

Atrial fibrillation is the most frequent chronic arrhythmia in patients with chronic kidney disease. Oral anticoagulation with vitamin K antagonists and now direct oral anticoagulants have been and are the fundamental pillars for the prevention of thromboembolic events. However, there are no randomized clinical trials on the risk-benefit profile of oral anticoagulation in patients with chronic kidney disease stage 5 on peritoneal dialysis and there is little evidence in the literature in this population. The objective of our study was to know the prevalence, treatment and professionals involved in the management of atrial fibrillation in peritoneal dialysis patients. For this purpose, we performed a descriptive analysis through a survey sent to different peritoneal dialysis units in Spain. A total of 1,403 patients on peritoneal dialysis were included in the study, of whom 186 (13.2%) had non-valvular atrial fibrillation. In addition, the assessment of the scores of thromboembolic and bleeding risks for the indication of oral anticoagulation was mainly carried out by the cardiologist (60% of the units), as well as its prescription (cardiologist 47% or in consensus with the nephrologist 43%). In summary, patients on peritoneal dialysis have a remarkable prevalence of non-valvular atrial fibrillation. Patients frequently receive oral anticoagulation with vitamin K antagonists, as well as direct oral anticoagulants. The data obtained regarding the scores used for the assessment of thromboembolic and bleeding risk, treatment and involvement by Nephrology indicates that there is a need for training and involvement of the nephrologist in this pathology.

2.
Nefrología (Madrid) ; 44(2): 268-275, Mar-Abr. 2024. tab, ilus, graf
Artículo en Español | IBECS | ID: ibc-231577

RESUMEN

La fibrilación auricular (FA) es la arritmia crónica más frecuente en pacientes con enfermedad renal crónica (ERC). La anticoagulación oral con antagonistas de la vitamina K (AVK) y actualmente los anticoagulantes orales de acción directa (ACOD) han sido el pilar fundamental para la prevención de eventos tromboembólicos. Sin embargo, no existen ensayos clínicos aleatorizados de su perfil riesgo-beneficio en pacientes con ERC estadio 5 en diálisis peritoneal (DP) y son pocas las evidencias en la literatura sobre esta población. El objetivo del estudio fue conocer la prevalencia, tratamiento y profesionales implicados en el manejo de la FA en DP en nuestro entorno mediante el análisis descriptivo de una encuesta enviada a diferentes unidades de DP de España. Se incluyeron en el estudio 1.403 pacientes en programa de DP, de los cuales 186 (13,2%) presentaban FA no valvular (FANV). Además, observamos que la valoración de los scores para el inicio del tratamiento anticoagulante la realizaba mayoritariamente el cardiólogo (60% de los centros), así como la prescripción de anticoagulación (cardiólogo 47% o en conjunto con el nefrólogo 43%). En conclusión, los pacientes en DP presentan una notable prevalencia de FANV. Reciben frecuentemente anticoagulación oral (ACO) con AVK, así como con ACOD. Los datos obtenidos respecto a las escalas utilizadas para la valoración de riesgo tromboembólico y de sangrado, tratamiento e implicación por parte de Nefrología indican que existe una necesidad de formación e involucramiento del nefrólogo en esta patología.(AU)


Atrial fibrillation is the most frequent chronic arrhythmia in patients with chronic kidney disease. Oral anticoagulation with vitamin K antagonists and now direct oral anticoagulants have been and are the fundamental pillar for the prevention of thromboembolic events. However, there are no randomized clinical trials on the risk-benefit profile of oral anticoagulation in patients with chronic kidney disease stage 5 on peritoneal dialysis and there is little evidence in the literature in this population. The objective of our study was to know the prevalence, treatment and professionals involved in the management of atrial fibrillation in peritoneal dialysis patients. For this purpose, we performed a descriptive analysis through a survey sent to different peritoneal dialysis units in Spain. A total of 1403 patients on peritoneal dialysis were included in the study, of whom 186 (13.2%) had non-valvular atrial fibrillation. In addition, the assessment of the scores of thromboembolic and bleeding risks for the indication of oral anticoagulation was mainly carried out by the cardiologist (60% of the units), as well as its prescription (cardiologist 47% in consensus with the nephrologist 43%). In summary, patients on peritoneal dialysis have a remarkable prevalence of non-valvular atrial fibrillation. Patients frequently receive oral anticoagulation with vitamin K antagonists, as well as direct oral anticoagulants. The data obtained regarding the scales used for the assessment of thromboembolic and bleeding risk, treatment and involvement by Nephrology indicates that there is a need for training and involvement of the nephrologist in this pathology.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Fibrilación Atrial/tratamiento farmacológico , Prevalencia , Diálisis Peritoneal , Vitamina K , Inhibidores del Factor Xa , Evaluación de Síntomas , Nefrología , Enfermedades Renales , Estudios Transversales , Estudios Retrospectivos
3.
Artif Organs ; 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38404240

RESUMEN

BACKGROUND: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out in 21 patients. All patients underwent six dialysis sessions with the same routine dialysis parameters; only the dialyzer and/or the dialysis modality varied: FX80 in HD, FDY 180 in HD, Clearum HS17 in HDF, Elisio 19H in HDF, Vitapes 180 in HDF, and FX80 in post-dilution HDF. The reduction ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, κFLC, prolactin, α1 -microglobulin, α1 -acid glycoprotein, λFLC, and albumin were compared intraindividually. Dialysate albumin loss was also measured. RESULTS: Both membranes FDY and FX80 are high-flux dialyzers and are applied here in high-flux HD. The average RR of ß2 -microglobulin was slightly lower in the two HD treatments than in the HDF treatments. Comparison of dialysis treatments revealed that the PEPA FDY dialyzer in the HD modality was more effective than the FX80 dialyzer in high-flux HD and was as effective as post-dilution HDF, especially in terms of myoglobin, κFLC, prolactin, α1 -microglobulin, and λFLC RRs. The FDY treatments obtained similar albumin RR in blood and slightly higher dialysate albumin loss, although the values were clinically acceptable. CONCLUSIONS: The most recently developed PEPA dialyzers in the HD modality were as effective as all treatments in the HDF modality and were clearly superior to high-flux helixone HD treatment. These results confirm that this dialyzer should be categorized within the medium cut-off (MCO) membrane classification.

4.
Kidney Int Rep ; 9(2): 266-276, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38344718

RESUMEN

Introduction: This study aimed to evaluate the association between the use of remote patient monitoring (RPM) in patients on automated peritoneal dialysis (APD) and the Standardized Outcomes in Nephrology in peritoneal dialysis (SONG-PD) clinical outcomes. Methods: A prospective and multicenter cohort study was conducted on patients with advanced chronic kidney disease on APD, recruited at 16 Spanish Hospitals, between June 1 and December 31, 2021. Patients were divided into 2 cohorts, namely patients on APD with RPM (APD-RPM) and patients on APD without RPM. The primary endpoints were the standardized outcomes of the SONG-PD clinical outcomes: PD-associated infection, cardiovascular disease (CVD), mortality rate, technique survival, and life participation (assessed as health-related quality of life [QoL]). Propensity score matching (PSM) was used to evaluate the association of RPM exposure with the clinical outcomes. Results: A total of 232 patients were included, 176 (75.9%) in the APD-RPM group and 56 (24.1%) in the APD-without-RPM group. The mean patient follow-up time was significantly longer in the APD-RPM group than in the APD-without-RPM group (10.4 ± 2.8 vs. 9.4 ± 3.1 months, respectively; P = 0.02). In the overall study sample, the APD-RPM group was associated with a lower mortality rate (hazard ratio [HR]: 0.08; 95% confidence interval [CI]: 0.01 to 0.69; P = 0.020) and greater technique survival rate (HR: 0.25; 95% CI: 0.11 to 0.59; P = 0.001). After PSM, APD-RPM continued to be associated with better technique survival (HR: 0.23; 95% CI: 0.06 to 0.83; P = 0.024). Conclusion: The use of RPM programs in patients on APD was associated with better survival of the technique and lower mortality rates. However, after PSM, only technique survival was significant.

5.
Nefrología (Madrid) ; 43(6): 750-756, nov.- dec. 2023. graf, tab
Artículo en Español | IBECS | ID: ibc-228013

RESUMEN

Introducción El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió dos sesiones de diálisis en las que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138,14 mmol/L con 5008 vs. 138,81 mmol/L con 6008) y final (139,58 mmol/L vs. 140,97 mmol/L), así como en la conductividad real obtenida (13,97 vs. 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores (AU)


Introduction The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusión The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors (AU)


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Soluciones para Hemodiálisis/química , Insuficiencia Renal Crónica/terapia , Sodio/sangre , Sodio/metabolismo , Técnicas Biosensibles
6.
Am J Nephrol ; 54(7-8): 291-298, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37311444

RESUMEN

INTRODUCTION: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients' salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. METHODS: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients' usual Na diet and again after another week with more restricted Na intake. RESULTS: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. CONCLUSIONS: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.


Asunto(s)
Cloruro de Sodio Dietético , Sodio , Humanos , Estudios Prospectivos , Diálisis Renal/métodos , Dieta Hiposódica , Presión Sanguínea , Aumento de Peso
7.
Clin Kidney J ; 16(5): 859-867, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37151418

RESUMEN

Background: A key feature of dialysis treatment is the prescription of dialysate sodium (Na). This study aimed to describe the practical implementation of a new automated dialysate Na control biosensor and to assess its tolerance and the beneficial clinical effects of isonatraemic dialysis. Methods: A prospective study was carried out in 86 patients who, along with their usual parameters, received the following five consecutive phases of treatment for 3 weeks each: phase 0: baseline 5008 machine; phases 1 and 2: 6008 machine without activation of the Na control biosensor and the same fixed individualized Na dialysate prescription or adjusted to obtain similar conductivity to phase 0; phases 3 and 4: activated Na control to isonatraemic dialysis (Na dialysate margins 135-141 or 134-142 mmol/L). Results: When the Na control was activated, the few episodes of cramps or hypotension disappeared when the lower dialysate Na margin was increased by 1 or 2 mmol/L. The activated Na control module showed significant differences compared with baseline and the non-activated Na module in final serum Na values, diffusive Na balance, and changes in pre- to postdialysis plasma Na values. The mean predialysis systolic blood pressure value was significantly lower in phase 4 than in phase 1. There were no significant differences in total Na balance in the four 6008 phases evaluated. Conclusions: The implementation of the automated dialysate Na control module is a useful new tool, which reduced the diffusive load of Na with good tolerance. The module had the advantages of reducing thirst, interdialytic weight gain and intradialytic plasma Na changes.

8.
Blood Purif ; 52(1): 68-74, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35551384

RESUMEN

INTRODUCTION: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. RESULTS: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. CONCLUSIONS: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.


Asunto(s)
Hemodiafiltración , Diálisis Renal , Humanos , Estudios Prospectivos , Hemodiafiltración/efectos adversos , Albúminas , Soluciones para Diálisis
9.
Nefrologia (Engl Ed) ; 43(6): 750-756, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38242765

RESUMEN

INTRODUCTION: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. MATERIAL AND METHODS: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). RESULTS: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14mmol/L with 5008 vs. 138.81mmol/L with 6008) and final plasma sodium (139.58mmol/L vs. 140.97mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1mS/cm). The ΔPNa also increased significantly. CONCLUSION: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors.


Asunto(s)
Diálisis Renal , Sodio , Humanos , Diálisis Renal/efectos adversos , Soluciones para Diálisis
10.
Clin Kidney J ; 15(12): 2292-2299, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36381368

RESUMEN

Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF). Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers. The reduction ratios (RRs) of urea, creatinine, ß2-microglobulin, myoglobin, kappa free immunoglobulin light chain (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda (λFLC) and albumin were compared. Dialysate albumin loss was also measured. Results: The differences in efficacy between the evaluated dialyzers were minimal in small molecules and even up to the size of ß2-microglobulin. The main differences were found between myoglobin, κFLC, prolactin, α1-microglobulin and λFLC RRs, in which all four MCO dialyzers, with similar efficacy, were clearly superior to HD and slightly inferior to HDF treatment. Albumin losses in the dialysate with HD dialyzers were <1 g and between 1.5 and 2.5 g in HDx and HDF. The global removal score values were similar in all four HDx treatments, and again significantly higher than those with HD. Conclusions: The results of the four MCO dialyzers evaluated in this study showed good efficiency, with no significant performance differences between them while being completely safe in terms of albumin loss. Likewise, the study confirms the superiority of HDx over high-flux HD with an efficacy close to that of post-dilution HDF.

11.
J Nephrol ; 35(3): 769-778, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35191008

RESUMEN

INTRODUCTION: Given the increased COVID-19 observed in kidney transplant recipients (KTRs) and haemodialysis patients, several studies have tried to establish the efficacy of mRNA vaccines in these populations by evaluating their humoral and cellular responses. However, there is currently no information on clinical protection (deaths and hospitalizations), a gap that this study aims to fill. METHODS: Observational prospective study involving 1,336 KTRs and haemodialysis patients from three dialysis units affiliated to Hospital Clínic of Barcelona, Spain, vaccinated with two doses of mRNA-1273 (Moderna) or BNT162b2 (Pfizer-BioNTech) SARS-CoV-2 mRNA vaccines. The outcomes measured were SARS-CoV-2 infection diagnosed by a positive RT-PCR fourteen days after the second vaccine dose, hospital admissions derived from infection, and a severe COVID-19 composite outcome, defined as either ICU admission, invasive and non-invasive mechanical ventilation, or death. RESULTS: Six per cent (18/302) of patients on haemodialysis were infected, of whom four required hospital admission (1.3%), only one (0.3%) had severe COVID-19, and none of them died. In contrast, 4.3% (44/1034) of KTRs were infected, and presented more hospital admissions (26 patients, 2.5%), severe COVID-19 (11 patients, 1.1%) or death (4 patients, 0.4%). KTRs had a significantly higher risk of hospital admission than HD patients, and this risk increased with age and male sex (HR 3.37 and 4.74, respectively). CONCLUSIONS: The study highlights the need for booster doses in KTRs. In contrast, the haemodialysis population appears to have an adequate clinical response to vaccination, at least up to four months from its administration.


Asunto(s)
COVID-19 , Trasplante de Riñón , Vacuna BNT162 , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/prevención & control , Humanos , Incidencia , Trasplante de Riñón/efectos adversos , Masculino , Estudios Prospectivos , Diálisis Renal/efectos adversos , SARS-CoV-2
12.
PLoS One ; 16(12): e0258440, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34882678

RESUMEN

Adapted automated peritoneal dialysis (aAPD), comprising a sequence of dwells with different durations and fill volumes, has been shown to enhance both ultrafiltration and solute clearance compared to standard peritoneal dialysis with constant time and volume dwells. The aim of this non-interventional study was to describe the different prescription patterns used in aAPD in clinical practice and to observe outcomes characterizing volume status, dialysis efficiency, and residual renal function over 1 year. Prevalent and incident, adult aAPD patients were recruited during routine clinic visits, and aAPD prescription, volume status, residual renal function and laboratory data were documented at baseline and every quarter thereafter for 1 year. Treatments were prescribed according to the nephrologist's medical judgement in accordance with each center's clinical routine. Of 180 recruited patients, 160 were analyzed. 27 different aAPD prescription patterns were identified. 79 patients (49.4%) received 2 small, short dwells followed by 3 long, large dwells. During follow-up, volume status changed only marginally, with visit mean values ranging between 1.59 (95% confidence interval: 1.19; 1.99) and 1.97 (1.33; 2.61) L. Urine output and creatinine clearance decreased significantly, accompanied by reductions in ultrafiltration and Kt/V. 25 patients (15.6%) received a renal transplant and 15 (9.4%) were changed to hemodialysis. Options for individualization offered by aAPD are actually used in practice for optimized treatment. Changes observed in renal function and dialysis efficiency measures reflect the natural course of chronic kidney disease. No safety events were observed during the study period.


Asunto(s)
Fallo Renal Crónico/terapia , Fallo Renal Crónico/orina , Diálisis Peritoneal , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Estudios Prospectivos
13.
Nefrología (Madrid) ; 41(5): 556-565, sep.-oct. 2021. tab, ilus
Artículo en Español | IBECS | ID: ibc-227935

RESUMEN

Introducción: Los pacientes en hemodiálisis (HD) suelen tener una condición física mermada y elevado sedentarismo. La consolidación de programas de ejercicio físico en las unidades de diálisis está limitada por barreras como la seguridad inherente a estos programas y la falta de recursos. Objetivos: Evaluar la eficacia y seguridad en la implantación de un programa de ejercicio físico intradiálisis (EFI) sobre la condición física de los pacientes con un equipo multidisciplinar (fisioterapeuta y auxiliares de enfermería). Material y métodos: Estudio cuasiexperimental pre-post unicéntrico prospectivo de 6 meses en 34 pacientes. Intervención con EFI combinado 2 días a la semana, evaluándose de forma basal y final la capacidad cardiorrespiratoria (6MWT), fuerza muscular (HG, dinamometría de cuádriceps y 10STS), la composición corporal (bioimpedanciometría) y la capacidad coordinativa (Timed Up and Go test). La seguridad se valoró registrando las incidencias relacionadas con el acceso vascular, la estabilidad hemodinámica y el perfil de rellenado vascular (RBV) durante las sesiones. También se registró la adherencia al programa así como parámetros analíticos habituales. Resultados: La adherencia al programa de EFI fue elevada (70,8%). Se constató una mejora significativa de 47m (p<0,001) en el 6MWT; un incremento medio de 1,6kg (p=0,007) en el HG para la fuerza de extremidades superiores y en las extremidades inferiores (10STS p=0,003; dinamometría p<0,05). Respecto a la seguridad, no se detectaron incidencias ni diferencias significativas en el RBV. Conclusiones: Un programa de EFI combinado favorece la mejora de la condición física de los pacientes en HD sin comprometer la seguridad del tratamiento. Es aconsejable un equipo multidisciplinar para implantar y dar continuidad eficazmente a un programa de EFI. (AU)


Introduction: Patients undergoing hemodialysis (HD) are characterized by a poor physical condition and a substantial sedentary profile. The implementation of physical exercise programs in the hemodialysis units is usually limited by the inherent safeness and the lack of appropriate resources. Objectives: We aimed to evaluate the impact and safety outcomes of the implementation of an intradialytic physical exercise program (IPE) by a multidisciplinary team (physiotherapist and nursing assistant) in the physical condition of the patients. Material and methods: This six months single-centre and experimental pre-post prospective study was carried out in 34 patients. A two day-week combined IPE intervention was implemented. The cardiopulmonary capacity (6MWT), muscular strength (HG, leg dynamometry and 10STS), body composition (bioimpedance) and coordination capacity (Timed Up and Go test) was assessed at the beginning and at the end of the study. Safety was evaluated by means of the number of issues regarding the vascular access, the hemodynamic stability as well as the vascular refilling profile (RBV) in each session. The adhesion to the program was also registered. Additionally, analytical parameters were recorded. Results: The adhesion to an IPE program was high (70.8%). A significant improvement of the cardiopulmonary capacity (6MWT average increase 47m; p<0.001), superior limbs (HG average increase of 1.6kg; p=0.007) as well as the lower extremities (10STS; p=0.003; dynamometry p<0.05). Regarding safeness, there were no incidences neither significant difference in the RBV. Conclusions: A combined IPE may contribute to the improvement of the physical condition of the patients as well as ensures a safe development of the HD treatment. We suggest a multidisciplinary team in order to efficiently establish an IPE program. (AU)


Asunto(s)
Humanos , Ejercicio Físico , Diálisis Renal , Eficacia , Estudios Prospectivos , Seguridad , Fuerza Muscular
14.
Clin Kidney J ; 14(3): 1004-1013, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34141409

RESUMEN

BACKGROUND: Metabolic acidosis is a common problem in haemodialysis patients, but acidosis overcorrection has been associated with higher mortality. There is no clear definition of the optimal serum bicarbonate target or dialysate bicarbonate. This study analysed the impact of reducing dialysate bicarbonate from 35 to 32 mEq/L on plasma bicarbonate levels in a cohort of patients treated with online haemodiafiltration (OL-HDF). METHODS: We performed a prospective cohort study with patients in a stable chronic OL-HDF programme for at least 12 months in the Hospital Clinic of Barcelona. We analysed pre- and post-dialysis total carbon dioxide(TCO2) before and after dialysate bicarbonate reduction from 35 to 32 mEq/L, as well as the number of patients with a pre- and post-dialysis TCO2 within 19-25 and ≤29 mEq/L, respectively, after the bicarbonate modification. Changes in serum sodium, potassium, calcium, phosphorous and parathyroid hormone (PTH) were also assessed. RESULTS: We included 84 patients with a 6-month follow-up. At 6 months, pre- and post-dialysis TCO2 significantly decreased (26.78 ± 1.26 at baseline to 23.69 ± 1.92 mEq/L and 31.91 ± 0.91 to 27.58 ± 1.36 mEq/L, respectively). The number of patients with a pre-dialysis TCO2 >25 mEq/L was significantly reduced from 80 (90.5%) to 17 (20.2%) and for post-dialysis TCO2 >29 mEq/L this number was reduced from 83 (98.8%) to 9 (10.7%). PTH significantly decreased from 226.09 (range 172-296) to 182.50 (125-239) pg/mL at 6 months (P < 0.05) and post-dialysis potassium decreased from 3.16 ± 0.30 to 2.95 ± 0.48 mEq/L at 6 months (P < 0.05). Sodium, pre-dialysis potassium, calcium and phosphorous did not change significantly. CONCLUSIONS: Reducing dialysate bicarbonate concentration by 3 mEq/L significantly and safely decreased pre- and post-dialysis TCO2, avoiding acidosis overcorrection and improving secondary hyperparathyroidism control. An individualized bicarbonate prescription (a key factor in the adequate control of acidosis) according to pre-dialysis TCO2 is suggested based on these results.

17.
Artif Organs ; 45(10): 1195-1201, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33978975

RESUMEN

The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.


Asunto(s)
Hemodiafiltración/instrumentación , Fallo Renal Crónico/terapia , Diálisis Renal/instrumentación , Anciano , Anciano de 80 o más Años , alfa-Globulinas/análisis , Creatinina/sangre , Femenino , Hemodiafiltración/métodos , Humanos , Masculino , Persona de Mediana Edad , Mioglobina/sangre , Orosomucoide/análisis , Seguridad del Paciente , Prolactina/sangre , Estudios Prospectivos , Diálisis Renal/métodos , Resultado del Tratamiento , Urea/sangre , Microglobulina beta-2/sangre
18.
Artif Organs ; 45(9): E317-E323, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33908062

RESUMEN

Toray has created a new generation of dialyzers, the polysulphone (TS) UL series, and polymethylmethacrylate (PMMA) NF-U series, which offer enhanced efficacy over the previous TS-S series and NF-H series. The aim of this study was to evaluate the safety and efficacy of these dialyzer series versus contrasted expanded hemodialysis (HDx) and postdilution hemodiafiltration (HDF). We conducted a prospective study in 12 patients. Each patient underwent six dialysis sessions: FX80 Cordiax in HD, Toraysulfone TS-1.8 UL in HD, Theranova 400 in HDx, polymethylmethacrylate (PMMA) NF-2.1 U in HDF, Toraysulfone TS-2.1 UL in HDF, and FX80 Cordiax in HDF. The removal ratios (RRs) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. The RRs for ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, and α1 -acid glycoprotein were higher with the TS-2.1 UL and FX80 Cordiax dialyzers in HDF than those obtained with HD treatments and NF-2.1 U in HDF. The ß2 -microglobulin, myoglobin, and prolactin RRs were also higher with HDx than those obtained with HD treatments. The myoglobin and prolactin RRs were higher with TS-1.8 UL in HD than those obtained with helixone dialyzers in HD. Dialysate albumin loss was less than 3 g in all situations except in TS-2.1 UL in HDF. The highest global removal score values were obtained with the TS-2.1 UL and helixone dialyzers in HDF. Significant differences were found between all study situations. In conclusion, the new generation dialyzers, Toraysulfone TS Series UL and PMMA NF-U series, show excellent behaviour and tolerance in HD and HDF, representing an upgrade versus their predecessor series. The higher permeability of the TS UL series has been proven with higher efficiency in HD and maximum performance in HDF. The new PMMA NF-U series allows the use of HDF with good efficiency and complete safety.


Asunto(s)
Hemodiafiltración/instrumentación , Enfermedades Renales/terapia , Membranas Artificiales , Polímeros/química , Polimetil Metacrilato/química , Sulfonas/química , Anciano , Biomarcadores/sangre , Femenino , Humanos , Enfermedades Renales/sangre , Masculino , Persona de Mediana Edad , Estudios Prospectivos
19.
Cardiovasc Drugs Ther ; 35(3): 521-532, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32651897

RESUMEN

PURPOSE: Chronic kidney disease (CKD) associates with inflammatory and prothrombotic phenotypes, resulting in higher cardiovascular risk. Factor Xa displays functions beyond coagulation, exhibiting proinflammatory effects. The aim of the present study was to investigate whether a direct FXa inhibitor protects from the endothelial dysfunction (ED) caused by uremia. METHODS: Macro (HUVEC) and microvascular (HMEC) endothelial cells (ECs) were exposed to serum from uremic patients or healthy donors, in absence and presence of apixaban (60 ng/ml). We evaluated changes in surface VCAM-1 and ICAM-1, intracellular eNOS, reactive oxygen species (ROS), and von Willebrand Factor (VWF) production by immunofluorescence, reactivity of the extracellular matrix (ECM) towards platelets, and intracellular signaling. RESULTS: ECs exposed to uremic serum triggered dysregulation of all the parameters. Presence of apixaban resulted in decreased expression of VCAM-1 (178 ± 14 to 89 ± 2% on HMEC and 324 ± 71 to 142 ± 25% on HUVEC) and ICAM-1 (388 ± 60 to 111 ± 10% on HMEC and 148 ± 9% to 90 ± 7% on HUVEC); increased eNOS (72 ± 8% to 95 ± 10% on HMEC); normalization of ROS levels (173 ± 21 to 114 ± 13% on HMEC and 165 ± 14 to 127 ± 7% on HUVEC); lower production of VWF (168 ± 14 to 92 ± 4% on HMEC and 151 ± 22 to 99 ± 11% on HUVEC); and decreased platelet adhesion onto ECM (134 ± 22 to 93 ± 23% on HMEC and 161 ± 14 to 117 ± 7% on HUVEC). Apixaban inhibited p38MAPK and p42/44 activation in HUVEC (139 ± 15 to 48 ± 15% and 411 ± 66 to 177 ± 57%, respectively) (p < 0.05 vs control for all parameters). CONCLUSION: Anti-FXa strategies, such as apixaban, prevented ED caused by the uremic milieu, exhibiting anti-inflammatory and antioxidant properties and modulating the reactivity of the ECM.


Asunto(s)
Inhibidores del Factor Xa/farmacología , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Pirazoles/farmacología , Piridonas/farmacología , Uremia/fisiopatología , Células Endoteliales/efectos de los fármacos , Matriz Extracelular/efectos de los fármacos , Humanos , Inflamación/fisiopatología , Molécula 1 de Adhesión Intercelular/efectos de los fármacos , Óxido Nítrico Sintasa de Tipo III/efectos de los fármacos , Fenotipo , Especies Reactivas de Oxígeno/metabolismo , Transducción de Señal/efectos de los fármacos , Molécula 1 de Adhesión Celular Vascular/efectos de los fármacos , Factor de von Willebrand/efectos de los fármacos
20.
Nefrologia (Engl Ed) ; 41(5): 556-565, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-36165138

RESUMEN

INTRODUCTION: Patients undergoing hemodialysis (HD) are characterized by a poor physical condition and a substantial sedentary profile. The implementation of physical exercise programs in the hemodialysis units is usually limited by the inherent safeness and the lack of appropriate resources. OBJECTIVES: We aimed to evaluate the impact and safety outcomes of the implementation of an intradialytic physical exercise program (IPE) by a multidisciplinary team (physiotherapist and nursing assistant) in the physical condition of the patients. MATERIAL AND METHODS: This six months single-centre and experimental pre-post prospective study was carried out in 34 patients. A two day-week combined IPE intervention was implemented. The cardiopulmonary capacity (6MWT), muscular strength (HG, leg dynamometry and 10STS), body composition (bioimpedance) and coordination capacity (Timed Up and Go test) was assessed at the beginning and at the end of the study. Safety was evaluated by means of the number of issues regarding the vascular access, the hemodynamic stability as well as the vascular refilling profile (RBV) in each session. The adhesion to the program was also registered. Additionally, analytical parameters were recorded. RESULTS: The adhesion to an IPE program was high (70.8%). A significant improvement of the cardiopulmonary capacity (6MWT average increase 47 m; p < 0.001), superior limbs (HG average increase of 1.6 kg; p = 0.007) as well as the lower extremities (10STS; p = 0.003; dynamometry p < 0.05). Regarding safeness, there were no incidences neither significant difference in the RBV. CONCLUSIONS: A combined IPE may contribute to the improvement of the physical condition of the patients as well as ensures a safe development of the HD treatment. We suggest a multidisciplinary team in order to efficiently establish an IPE program.


Asunto(s)
Ejercicio Físico , Equilibrio Postural , Terapia por Ejercicio , Humanos , Estudios Prospectivos , Estudios de Tiempo y Movimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...